Sign In
 

Video Instructions - Transom Housing Installation

Launch in external player

Transom Adaptor Installation - Models 12JC & 12JG Only (Next two steps)

  1. Slide the large O-ring over the nozzle and bowl assemblies and into the groove around the pump bowl perimeter, as shown.
  2. Slide a NEW transom adaptor gasket over the pump bowl and into place against the transom.  A few dabs of silicone sealer will hold the gasket in approximate position.  Now, bring the transom adaptor up over the nozzle and bowl.  Feed the steering cable and the reverse cable through the correct holes in the transom adaptor.  Start the attaching bolts through the adaptor, through the gasket, and into the transom.  Bring the bolts up just FINGER TIGHT.
  3. After all the bolts have been started tighten each one securely, working in an alternating crossover pattern.  Now lay down a neat and even bead of silicone sealer between the transom adaptor and the boat transom, also between the pump bowl and the transom adaptor.

 


 